Unique Safety Services
sales@uniquesafety.co.in

Drager PAC 7000 gas detector

Drager PAC 7000 gas detector

Product Details:

  • Shelf Life 2-3 years typical sensor life (gas type dependent)
  • Disposability Reusable
  • Usage Gas Detection
  • Features Shock resistant, dust and water-resistant (IP65/67), replaceable sensor and battery, data logging, visual and audible alarms
  • Function Single-gas detection (various toxic gases, O2, CO, H2S, others)
  • Application Personal protection against hazardous gases
  • Warranty 1 Year
X

Drager PAC 7000 gas detector Price And Quantity

  • 1 Piece
  • Sensor and device self-test with prompt alerts
  • 10 to 90 % RH (non-condensing)
  • Sturdy alligator belt clip
  • Electrochemical (specific for detected gas)
  • IP65 / IP67
  • Visual, Audible (90 dB) and Vibrating
  • < 15 seconds (gas dependent)
  • Yes (with event recording)
  • -30 °C to +55 °C
  • Backlit LCD Display
  • CR2 battery (replaceable, up to 2 years life)

Drager PAC 7000 gas detector Product Specifications

  • Shock resistant, dust and water-resistant (IP65/67), replaceable sensor and battery, data logging, visual and audible alarms
  • Black
  • Yes
  • Yes
  • Single-gas detection (various toxic gases, O2, CO, H2S, others)
  • 1 Year
  • Personal protection against hazardous gases
  • Pocket-sized (approx. 84 x 64 x 20 mm)
  • Unisex
  • Drager PAC 7000 gas detector Chennai
  • Robust polycarbonate housing
  • Compact
  • Gas Detection
  • Approx. 120g including battery
  • Polycarbonate housing with rubber protection
  • 2-3 years typical sensor life (gas type dependent)
  • Reusable
  • Sensor and device self-test with prompt alerts
  • 10 to 90 % RH (non-condensing)
  • Sturdy alligator belt clip
  • Electrochemical (specific for detected gas)
  • IP65 / IP67
  • Visual, Audible (90 dB) and Vibrating
  • < 15 seconds (gas dependent)
  • Yes (with event recording)
  • -30 °C to +55 °C
  • Backlit LCD Display
  • CR2 battery (replaceable, up to 2 years life)

Drager PAC 7000 gas detector Trade Information

  • 100 Piece Per Week
  • 7 Days

Product Description

Drager PAC 7000 gas detector Chennai

  • This single oxygen meter has easy on/off operation
  • 2 year battery life (typical) with replaceable 3V battery
  • Water-resistant
  • Built-in concussion-proof boot
  • It is equipped with internal vibrating alarm for high noise areas


Robust Design for Harsh Environments

The Drager PAC 7000 is built with a polycarbonate housing and rubberized protection, making it shock-resistant and suitable for tough field conditions. With an ingress protection rating up to IP67, it is resilient against dust and water, ensuring continued operation even in unpredictable weather or hazardous industrial environments.


Reliable and Fast Gas Detection

Equipped with electrochemical sensors specific to each detected gas, the PAC 7000 delivers rapid response in under 15 seconds (depending on the gas). Its efficient sensor enables continuous air monitoring, providing timely alerts for dangerous conditions with visual, audible, and vibrating alarms.


Convenient Personal Safety Features

The PAC 7000s compact size and sturdy alligator belt clip allow for effortless attachment and portability. The backlit LCD display offers clear readings in low-light environments, while data logging and event recording features support safety compliance and incident tracking for workplace monitoring.

FAQs of Drager PAC 7000 gas detector:


Q: How does the Drager PAC 7000 alert the user in hazardous gas situations?

A: The PAC 7000 provides three types of alarms: visual alerts, audible alarms reaching 90 dB, and vibrating notifications. This multimodal approach ensures users are promptly alerted to gas dangers, even in noisy or challenging environments.

Q: What is the process for replacing the battery and sensor in the Drager PAC 7000?

A: The device uses a readily replaceable CR2 battery, which typically lasts up to two years. Sensors are replaceable as well, with user-friendly access for maintenance, ensuring continued functionality and reducing downtime.

Q: When should the PAC 7000 undergo servicing or self-tests?

A: The PAC 7000 conducts automatic self-tests for both the sensor and device. It provides prompt alerts if maintenance is required, helping ensure reliable performance and user safety. Regular sensor checks and battery replacements are advised for optimal usage.

Q: Where can the Drager PAC 7000 be used effectively?

A: This detector is designed for personal use in varied industrial environments, such as chemical plants, manufacturing sites, confined spaces, and any location where exposure to toxic gases may occur. Its robust and waterproof design ensures reliable operation across diverse workplaces.

Q: What gases can the Drager PAC 7000 detect?

A: The PAC 7000 supports detection of a range of single gases, such as oxygen (O2), carbon monoxide (CO), hydrogen sulfide (H2S), and other toxic gases, depending on the sensor installed. Users can select the specific sensor to match their application needs.

Q: How does data logging benefit users of the PAC 7000?

A: Data logging capabilities allow the device to automatically record events and exposures to hazardous gases. This supports compliance, incident review, and ongoing safety audits, providing valuable records for both users and safety managers.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Portable Gas Detectors' category



UNIQUE SAFETY SERVICES
Mumbai, Maharashtra, India
Back to top
trade india member
UNIQUE SAFETY SERVICES All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.